Parking facilities![]()
Number of disabled parking spaces 5
Total number of parking spaces 0
disabled parking signedYes
Surface marking of disabled parking spaces Yes
Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementasphalt
Disabled parking space, width 2.1 m 

Way to the entrance![]()
Distance from disabled parking space to main entrance 40 m
Distance from stopping zone to main entrance 20 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance tiles
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 170 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Separation of forms of traffic up to main entrance Yes
Height of separation 8 cm
Entrance to the building![]()
Height of door bell 160 cm 

Entry phones with visual indication of active status Yes
Entry phones with visual indication of connection No
Clear width at main entrance160 cm
Levelfree access through entranceYes
Surfacing of outdoor areas is firm and evenYes
Surfacing of outdoor areas, general Asphalt
Levelfree trails or pathsYes
Entrance landings Yes
Size of levelfree landings in front of entrance(s)300 cm
Clear width through entrance doors 110 cm
Lighting at entrance doors, reception, lobby, etc Yes
Interior design of the building![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 200 cm
Lift door must be automatic Yes
Clear opening width of lift door 160 cm
Width of lift car 160 cm
Depth of lift car 260 cm
Floor buttons, lowest 100 cm
Floor buttons, highest 125 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 3
Orientation signals (sound and light) in lift Light signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? No
Clear width, corridors 150 cm
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes 

Attention fields in building No
Marking on steps No marking
Handrails, position Both sides
Alternative to stairs (eg ramp, lift, stair lift)Yes
Guidedogs and indoor climate![]()
Access for guide dogsYes
Access for service dogs Yes
Communal areas are pet-free areas Yes
Personal service Yes
Distance to public transport 150 m
Free access for accompanying persons Yes
Orientation signage for essential facilitiesGood signage in many places
Other information