Herlev Hudklinik Monika Gniadecka
All information about Herlev Hudklinik Monika Gniadecka
Information for

Accessibility information
Parking facilities![]()
Number of parking spaces for cars with a disabled parking permit2
Total number of parking spaces 10
Disabled parking space, width3.5 m
Disabled parking signedYes
Size of the disabled parking marked on the pavementYes
Marked with wheelchair sign on the pavement No
Surfacing on disabled parking spaces The surfacing is even and firm
Type of surfacing Asphalt
From parking to entrance![]()
Distance from disabled parking space to main entrance 30 m
Distance from stopping zone to main entrance 10 m
Curbs leveled outYes
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance tiles
Generally passage width200 cm
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 150 cm
Free area, height 210 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Ramp
Stairs are availableNo
Width of the ramp150 cm
Slope of the ramp5 %
Length of ramp2.5 m
Højde på hjulværn0 cm
Transition to the ramp - leveledYes
Placement of handrailsNo Handrails 

The ramp surface is smooth and firmYes
Pavement on the ramp
Entrance to the building![]()
Levelfree access through entrance Yes
Height of threshold2.5 cm
Tresholds levelled out by sloping wedge No
Entrance landings Yes
Size of the landing in front of the entrance150 cm
Grate infront of the Entrance
Openings in grating (to protect guide dogs), length at main entrance 3 cm
Openings in grating (to protect guide dogs), width at main entrance 1 cm
Type of door at the entranceOne door
Clear width through entrance doors 80 cm
Door at the entranceThe door opens outwards
Operation of the doorMust be opened manually
Free space next to the opening side of the door80 cm
Free space before or after the front door300 cm
Entrance door, attractive and compressive force 4 kg
Lighting at entrance doorsYes
The entrance is signpostedYes
Changed surfacing in front of the entranceYes
Glass panel with horizontal marking Good marking in several places
Lift and stairs![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 200 cm
Lift door must be automatic Yes
Clear opening width of lift door 90 cm
Width of lift car 110 cm
Depth of lift car 220 cm
Floor buttons, lowest 85 cm
Floor buttons, highest 105 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 0
Orientation signals (sound and light) in lift Sound/light signal
Are floor levels announced by synthetic speech in lift? No
Stairs in the buildingYes
Number of steps20
The width of the stairs110 cm
Step height18 cm
Step depth28 cm
Marking on steps No marking
Height of stair guards90 cm
Handrails, height90 cm
Handrails, position One side 

Extended handrails by the stairs30 cm
Alternative to stairs (eg ramp, lift, stair lift)Yes
Lighting or marking of the stairsYes
Reception and waiting area![]()
Width of doors in building 85 cm
Height of thresholds in building 2.5 cm
Are there wedges at thresholds in excess of 2.5 cm? Yes
Doors, attractive/compressive force (heaviest non-entrance door) 2 kg
Clear width in area leading to counter, etc 150 cm
Height of counter 110 cm
Counter illumination No
Induction loop at counter No
Heigth of the card reader110 cm
Chairs with armrests available. Yes
Chairs with backrests available Yes
Seating height of chairs 46 cm
Interior design of the clinic![]()
Clear width, corridors 150 cm
Circulation areas can be used as guiding lines Yes
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Distance between sources of lighting 2 m
Consultation room![]()
Width of doors in building 85 cm
Height of thresholds in building 2.5 cm
Are there wedges at thresholds in excess of 2.5 cm? Yes
Shortest length of clear manoeuvring area 150 cm
Examination tables that can be lowered and raised in the examination room Yes
Lowest height of height-adjustable couches 50 cm
Lift i konsultationsrumNo
Chairs with armrests Yes
Chairs with backrests in examination rooms Yes
Seating height of chairs 45 cm
Toilet facilities![]()
Accessible toiletfacilitiesYes
Entrance landings in front of the toiletYes
Same floor level in front of the toilet and in the toiletroomYes
Lavatory door, width 76.5 cm 

Door to the toiletOpens outward
Free space next to the door (openingside)50 cm
Lavatory threshold, height 0 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 1 kg
Width of turning area in lavatory 150 cm
Length of turning area in lavatory 150 cm
Clear space on one side of lavatory bowl. 90 cm
Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl
Distance from lavatory bowl to back wall 70 cm
Lavatory bowl, height 48 cm
Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails Right and left side
Correct length of armrests by the toilet Yes
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. Yes
Height of wash basin80 cm
Easy-to-operate inside lock Difficult to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 95 cm
Height of paper towel holder 135 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Guidedogs![]()
Access for guide dogsYes
Access for service dogs Yes
Indoor climate![]()
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedNo
Communication![]()
Orientation signage for essential facilities
Other information
Last update: 12-03-2024 (Version 2)

Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96