Vingsted Hotel og Konferencecenter - lokale 9-12
All information about Vingsted Hotel og Konferencecenter - lokale 9-12
Information for
ALL
Accessibility information
Way to the entrance
Number of disabled parking spaces 5
Total number of parking spaces 75
disabled parking signedYes
Surface marking of disabled parking spaces Yes
Surfacing on disabled parking spaces The surfacing is even and firm
Disabled parking space, width 3.5 m
Number of parking spaces for vans 1
Entrance to the building
Distance from disabled parking space to main entrance 40 m
Distance from stopping zone to main entrance 2 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance asphalt or tile
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 150 cm
Free area, height 300 cm
Levelfree access up to entrance No
Type of levelling up to entrance Ramp
Gradient of levelling 10 %
Handrail position next to steps No handrail
Outdoor areas
Clear width at main entrance150 cm
Levelfree access through entranceYes
Entrance landings Yes
Clear width through entrance doors 90 cm
Alternative entrance to revolving door/swing door entrance Yes
Height of push button 90 cm
Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas With changed surfacing
Glass panel with horizontal marking Reasonable marking in several places
Access for guide dogsYes
Access for service dogs Yes
Interior design of the building
Guidedogs and indoor climate
Indicate depth of clear manoeuvring area measured at right angles to the door 200 cm
Lift door must be automatic Yes
Clear opening width of lift door 85 cm
Width of lift car 110 cm
Depth of lift car 140 cm
Floor buttons, lowest 130 cm
Floor buttons, highest 130 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 3
Orientation signals (sound and light) in lift Sound signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? No
Døre bortset fra indgangsdøre
Width of doors in building 80 cm
Doors, attractive/compressive force (heaviest non-entrance door) 2 kg
Indvendige gange og ramper
Clear width, corridors 150 cm
Corridors free of furniture Yes
Gradients exceeding 1:20 (5%)No
Ramp with gradient of 6.25 %
Lower landing, length 150 cm
Lower landing, width 150 cm
Turn on lower landing necessary Yes
Upper landing, length 170 cm
Upper landing, width 200 cm
Turn on upper landing necessary Yes
Distance between sources of lighting 3 m
Marking on steps All steps
Permanent railing at free-standing stairs Movable protection
Handrails, position Both sides
Alternative to stairs (eg ramp, lift, stair lift)Yes
Indretning af toilet- og baderum
Entrance landings in front of the toiletYes
Lavatory door, width 90 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 1.8 kg
Clear manoeuvring area in lavatories Yes
Width of turning area in lavatory 135 cm
Length of turning area in lavatory 145 cm
Clear space on one side of lavatory bowl. 96 cm
Position of clear space next to the lavatory bowlOn one side of lavatory bowl
Distance from lavatory bowl to back wall 80 cm
Lavatory bowl, height 42 cm
Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails Left side
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. No
Height of wash basin80 cm
Clear space under wash basinYes
Easy-to-operate inside lock Relatively easy to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 90 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Øvrige rum - foredragssal, tv-stue, restaurant
Chairs with armrests available. Yes
Chairs with backrests available Yes
Seating height of chairs 45 cm
Chairs without armrests for notetaker Yes
Clearance under tables 72 cm
Clear depth under table50 cm
Induction loop systems can be booked Yes
Sockets for notetaker's equipment Yes
Powerbeam screen Yes
Indeklima og rengøring
Mechanical exhaustionYes
Communal areas are non-smoking areas No
Communal areas are pet-free areas Yes
Signage in smoking and non-smoking areas Yes
Wall-to-wall carpeting used No
Wipeable surfaces Yes
Wipeable lamps and furniture Yes
Information, formidling og service
Orientation signage for essential facilitiesGood signage in many places
Simple and logically structured signs Simple and logic
Personal service Yes
Distance to public transport 500 m
Other information
Last update: 21-02-2012 (Version 1)
Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96