Godadgang Logo

Vallerødskolen - 1. Hovedbygning

Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning
Vallerødskolen - 1. Hovedbygning

All information about Vallerødskolen - 1. Hovedbygning

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces  

disabled parking signedYes

Surface marking of disabled parking spaces  Yes

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt or tile

Disabled parking space, width  3.5 m

Number of parking spaces for vans  

Distance from disabled parking space to main entrance  80 m

Distance from stopping zone to main entrance  30 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt or tile

Clear width in outdoor areas leading to main entrance  150 cm

Clear area, width 250 cm

Free area, height 250 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Ramp

Gradient of levelling  5 %

Curbs leveled outYes

slope on curb compensation15 %

Entrance to the building

Clear width at main entrance250 cm

Levelfree access through entranceYes

Position of handrails No handrail

Height of threshold2 cm

Marking of doorstepsYes

Entrance landings No Red

Openings in grating (to protect guide dogs), length at main entrance  0.9 cm

Openings in grating (to protect guide dogs), width at main entrance  3 cm

Clear width through entrance doors  85 cm

Entrance door, attractive and compressive force  5 kg Red

Door knobs and handles Easy to operate

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign and changed surfacing

Glass panel with horizontal marking  Reasonable marking in several places

Interior design of the school

Level access to lifts Yes

Indicate depth of clear manoeuvring area measured at right angles to the door 150 cm

Lift door must be automatic No Red

Clear opening width of lift door  90 cm

Width of lift car  100 cm

Depth of lift car  140 cm

Floor buttons, lowest  85 cm

Floor buttons, highest 85 cm

Buttons with tactile-sense orientation  Yes

Are easy-touch buttons used? No

Number of support handles in lift  

Orientation signals (sound and light) in lift  Sound signal

Stair lift and lifting platform, capacity  225 kg

Lifting platform - platform length  100 cm

Lifting platform - platform width  80 cm

Width of doors in building  80 cm

Height of thresholds in building  5 cm

Doors, attractive/compressive force (heaviest non-entrance door) 6 kg Red

Clear width, corridors  200 cm

Corridors free of furniture Yes

Gradients exceeding 1:20  (5%)No

Level-free circulation in building and level-free access to communal facilities  Yes

Attention fields in building  No

Marking on steps  All steps

Marked surfaces Tread and riser

Handrails, position Both sides

Alternative to stairs (eg ramp, lift, stair lift)Yes

Distance between sources of lighting 3 m

Toiletter

Entrance landings in front of the toiletYes Red

Lavatory door, width  85 cm

Lavatory doors can be opened/closed using a tractive or compressive force of  2.5 kg

Width of turning area in lavatory  155 cm

Length of turning area in lavatory  150 cm

Clear space on one side of lavatory bowl.  93 cm

Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl

Distance from lavatory bowl to back wall  77 cm

Lavatory bowl, height  48 cm Red

Operation of toilet flushing handleFlushing is elevated

Lavatory, position of support rails  Right and left side

Easy-to-operate taps Easy to operate

Possible to use washbasin when sitting on lavatory bowl.  No Red

Height of wash basin82 cm

Clear space under wash basinYes

Height of soap dispenser110 cm

Distance to soap50 cm

Easy-to-operate inside lock Difficult to operate

Locked doors can be opened from the outside in case of emergency  Yes

Mirror, lower edge  85 cm

Height of hand drier button120 cm

Ventilation system in lavatories  Yes

Wipeable surfaces  Yes

Non-glare illuminated mirror within easy reach   Yes

Interior pull handleNo

Interior design of the classrooms

Height of desk/counter used for experiments and exercises90 cm

Clear width between rows of tables150 cm

kitchen door, width85 cm

Height of steps leading to kichen0.5 cm

Kitchen door, attractive and compressive force  2.5 kg

Height of kitchen tabletop 90 cm

Is there a clear space under the kitchen tabletop? No Red

Adjustable tabletops in kitchen.  No Red

Minimum height of kitchen units and wall cupboards65 cm

Fittings and handles in kitchen are easy to operate 

Fittings and handles in kitchen are easy to operate 

Space for manoeuvring Yes

Minimum length of clear manoeuvring area 200 cm

Possible to position wheelchair immediately next to the machine 

Use of kitchen sink 

Distance from edge of kitchen tabletop to water taps 45 cm Red

Kitchen workstations 

Button type on cooker  Red

Mechanical exhaustion   Yes

Sockets for notetaker's equipment  Yes

Powerbeam screen  Yes

Guidedogs and indoor climate

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedNo Red

Allergy-friendly cleaning  mainly allergiapproved detergents

Thorough cleaning, other rooms  yearly

Wall-to-wall carpeting used  No

Wipeable surfaces Yes

Wipeable lamps and furniture  Yes

Orientation signage for essential facilitiesGood signage in many places

Distance to public transport 50 m

Accessibility-tested website 

Website may be read out loud No

 

Other information

Last update: 12-10-2015 (Version 1)

Ulla Kramer