Sundhedshuset Albertslund - 1. Genoptræningscenter via hovedindgangen
All information about Sundhedshuset Albertslund - 1. Genoptræningscenter via hovedindgangen
Information for

Accessibility information
Parking facilities![]()
Number of disabled parking spaces 5
disabled parking signedNo
Surface marking of disabled parking spaces Yes
Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementasphalt or tile
Disabled parking space, width 3.5 m
Distance from disabled parking space to main entrance 40 m
Distance from stopping zone to main entrance 40 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance asphalt or tile
Clear width in outdoor areas leading to main entrance 175 cm
Clear area, width 175 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Ramp
Gradient of levelling 3 %
Entrance to the building![]()
Clear width at main entrance250 cm
Levelfree access through entranceYes
Marking of doorstepsYes
Entrance landings Yes
Size of the landing infront of the entrance250 cm
Openings in grating (to protect guide dogs), length at main entrance 0.9 cm
Openings in grating (to protect guide dogs), width at main entrance 3 cm
Clear width through entrance doors 160 cm
Height of push button 98 cm
Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas With sign and changed surfacing
Glass panel with horizontal marking Poor marking in several places
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 250 cm
Lift door must be automatic Yes
Clear opening width of lift door 130 cm
Width of lift car 140 cm
Depth of lift car 250 cm
Floor buttons, lowest 95 cm
Floor buttons, highest 116 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 1
Orientation signals (sound and light) in lift Sound signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? Yes
Attention fields in building No
Marking on steps All steps
Marked surfaces Tread and riser
Handrails, position Both sides
Alternative to stairs (eg ramp, lift, stair lift)Yes
Reception and waiting room![]()
Chairs with armrests available. Yes
Chairs with backrests available Yes
Seating height of chairs 45 cm
Reception and waitingroom![]()
Width of doors in building 85 cm
Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg
Clear width, corridors 150 cm
Corridors free of furniture Yes
Circulation areas can be used as guiding lines Yes
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Distance between sources of lighting 3 m
Dressing rooms![]()
Entrance landings in front of the toiletYes
Lavatory door, width 85 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Width of turning area in lavatory 80 cm 

Length of turning area in lavatory 80 cm 

Clear space on one side of lavatory bowl. 85 cm 

Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl
Distance from lavatory bowl to back wall 84 cm
Lavatory bowl, height 48 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails Right and left side
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. No 

Height of wash basin79 cm
Clear space under wash basinYes
Height of soap dispenser110 cm
Easy-to-operate inside lock Easy to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 95 cm
Height of paper towel holder 136 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Entrance landings in front of the toiletYes
Lavatory door, width 86 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Width of turning area in lavatory 230 cm
Length of turning area in lavatory 150 cm
Clear space on one side of lavatory bowl. 160 cm
Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl
Distance from lavatory bowl to back wall 84 cm
Lavatory bowl, height 48 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails Right and left side
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. No 

Height of wash basin80 cm
Clear space under wash basinYes
Height of soap dispenser110 cm
Easy-to-operate inside lock Easy to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 95 cm
Height of paper towel holder 135 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Access to the consultation rooms![]()
Shortest length of clear manoeuvring area 150 cm
Clear manoeuvring area of 150 x 150 cm Yes
Toilet facilities![]()
Access for guide dogsYes
Access for service dogs Yes
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedNo 

Guidedogs![]()
Orientation signage for essential facilitiesGood signage in many places
Distance to public transport 250 m
Accessibility-tested website
Website may be read out loud Yes
Other information
Last update: 10-10-2016 (Version 1)

Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96