Godadgang Logo

Solvangskolen - Gymnastiksal

Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal
Solvangskolen - Gymnastiksal

All information about Solvangskolen - Gymnastiksal

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces  

Total number of parking spaces 30 

disabled parking signedYes

Surface marking of disabled parking spaces  Yes

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt

Disabled parking space, width  3 m Red

Number of parking spaces for vans  

Distance from disabled parking space to main entrance  30 m

Distance from stopping zone to main entrance  30 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt

Clear width in outdoor areas leading to main entrance  150 cm

Clear area, width 150 cm

Free area, height 300 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Ramp

Gradient of levelling  5 %

Curbs leveled outYes

Handrail position next to steps Both sides

Entrance to the building

Clear width at main entrance150 cm

Levelfree access through entranceYes

Height of threshold3 cm

Tresholds levelled out by sloping wedge Yes

Entrance landings Yes

Size of the landing infront of the entrance300 cm

Openings in grating (to protect guide dogs), length at main entrance  2 cm Red

Openings in grating (to protect guide dogs), width at main entrance  2 cm

Clear width through entrance doors  80 cm

Entrance door, attractive and compressive force  4 kg

Door knobs and handles Easy to operate

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign and changed surfacing

Indretning af bygningen

Marking on steps  All steps

Marked surfaces Tread and riser

Handrails, position Both sides

Alternative to stairs (eg ramp, lift, stair lift)Yes Yellow

Clear width, corridors  180 cm

Distance between sources of lighting 3 m

Omklædningsfaciliteter

Width of doors in building  80 cm

Changing room benches, width  35 cm

Changing room benches, length  450 cm

Changing room benches, seating height  45 cm

Lower clothing hooks, height  170 cm

Anti-glare mirror Yes

Closed changing cubicleNo

Separate changing rooms No

Clear manoeuvring area in bathrooms  Yes

Vendeareal ved bruseplads (bredde)150 cm

Vendeareal ved bruseplads (længde)150 cm

Access to shower  from all sides

Operation of shower Standing and sitting

Type of showerShower not adjustable

Minimum height for wall position of shower200 cm

Shower seat/stool  Neither shower seat nor shower stool Red

Walls with horizontal handrails in shower  

Walls with vertical handrails in shower 

Shower temperature and water controls easy to operateYes

Height of water and temperature control devices110 cm

Toiletter

accessible toilets at every levelNo

Generelle forhold

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedNo Red

Orientation signage for essential facilitiesGood signage in many places

 

Other information

Last update: 29-10-2020 (Version 1)

Ulla Kramer

Call us or write to us if you need more information about our services.

info@godadgang.dk - phone +45 51 34 35 96