Røntgenklinikken Trianglen
All information about Røntgenklinikken Trianglen
Information for
ALLAccessibility information
Parking facilities![]()
From parking to entrance![]()
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance tiles
Generally passage width150 cm
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 150 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Levelled out on ground
Entrance to the building![]()
Levelfree access through entrance No 

Rise of steps in front of the entrance22 cm
Position of handrails Both sides
Height of threshold4 cm 

Tresholds levelled out by sloping wedge No
Marking of doorstepsYes
Entrance landings No 

Type of door at the entranceOne door
Clear width through entrance doors 88 cm
Door at the entranceThe door opens inwards
Operation of the doorAutomatic door with censor
Lighting at entrance doorsYes
The entrance is signpostedYes
Glass panel with horizontal marking Reasonable marking in several places
Lift and stairs![]()
Attention fields in building No
Stairs in the buildingYes
Number of steps2
The width of the stairs93 cm
Step height21 cm
Step depth33 cm
Marking on steps All steps
Marked surfaces Tread and riser
Handrails, height80 cm
Handrails, position Both sides
Extended handrails by the stairs10 cm
Alternative to stairs (eg ramp, lift, stair lift)No 

Lighting or marking of the stairsYes
Reception and waiting area![]()
Width of doors in building 88 cm
Clear width in area leading to counter, etc 150 cm
Height of counter 100 cm
Counter illumination No
Induction loop at counter No
Possible to use your own FM receiver at the counter Yes
Heigth of the card reader95 cm
Chairs with armrests available. Yes
Chairs with backrests available Yes
Seating height of chairs 45 cm
Names called out Yes
Interior design of the clinic![]()
Width of doors in building 77 cm
Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg
Clear width, corridors 70 cm 

Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Distance between sources of lighting 3 m
Consultation room![]()
Shortest length of clear manoeuvring area 150 cm
Clear manoeuvring area of 150 x 150 cm Yes
Toilet facilities![]()
Accessible toiletfacilitiesNo 

Entrance landings in front of the toiletYes
Same floor level in front of the toilet and in the toiletroomYes
Lavatory door, width 78 cm
Door to the toiletOpens inward
Free space next to the door (openingside)30 cm 

Lavatory threshold, height 0.5 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Width of turning area in lavatory 45 cm 

Length of turning area in lavatory 80 cm 

Clear space on one side of lavatory bowl. 26 cm 

Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl
Distance from lavatory bowl to back wall 71 cm
Lavatory bowl, height 44 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails No armrests 

Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. No 

Height of wash basin88 cm
Clear space under wash basinYes
Easy-to-operate inside lock Difficult to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 135 cm
Height of paper towel holder 147 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Guidedogs![]()
Access for guide dogsYes
Access for service dogs Yes
Indoor climate![]()
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedYes
Communication![]()
Orientation signage for essential facilitiesGood signage in many places
Other information
Last update: 26-02-2026 (Version 2)
Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96
