Psykiater Mik Adsersen
All information about Psykiater Mik Adsersen
Information for
ALLAccessibility information
Parking facilities![]()
From parking to entrance![]()
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance asphalt or tile
Generally passage width150 cm
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 150 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Stairs 

Stairs are availableYes
Number of steps5
The width of the stairs95 cm
Marking of stepsNo marking of steps 

Steps are even and firmNo 

Type of pavement on the stairscement or concrete
Placement of handrails by the stairsBoth sides
Handrails, height90 cm
Field of attention by the stairsNo 

Entrance to the building![]()
Levelfree access through entrance No 

Rise of steps in front of the entrance15 cm
Height of threshold6 cm 

Tresholds levelled out by sloping wedge No
Marking of doorstepsYes
Entrance landings No 

Type of door at the entranceDouble doors
Clear width through entrance doors 62 cm 

Door at the entranceThe door opens inwards
Operation of the doorMust be opened manually
Entrance door, attractive and compressive force 10 kg 

Door knobs and handles Easy to operate
The height of the panel or access control125 cm 

Lighting at entrance doorsYes
The entrance is signpostedYes
Changed surfacing in front of the entranceNo
Glass panel with horizontal marking Good marking in several places
Lift and stairs![]()
Attention fields in building No
Stairs in the buildingYes
Number of steps2
The width of the stairs220 cm
Step height19 cm
Step depth28 cm
Marking on steps All steps
Marked surfaces Tread and riser
Handrails, position None handrail 

Reception and waiting area![]()
Width of doors in building 86 cm
Free space next to the door (openingside)8 cm 

Height of thresholds in building 6 cm
Are there wedges at thresholds in excess of 2.5 cm? No 

Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg
Chairs with armrests available. Yes
Chairs with backrests available Yes
Seating height of chairs 45 cm
Names called out Yes
Interior design of the clinic![]()
Width of doors in building 68 cm 

Height of thresholds in building 4 cm
Are there wedges at thresholds in excess of 2.5 cm? No 

Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg
Clear width, corridors 100 cm 

Corridors free of furniture Yes
Circulation areas can be used as guiding lines Yes
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Distance between sources of lighting 3 m
Consultation room![]()
Shortest length of clear manoeuvring area 200 cm
Clear manoeuvring area of 150 x 150 cm Yes
Toilet facilities![]()
Entrance landings in front of the toiletNo 

Same floor level in front of the toilet and in the toiletroomYes
Lavatory door, width 68 cm 

Door to the toiletOpens outward
Lavatory threshold, height 4 cm
Sloping wedge at thresholdsNo 

Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Width of turning area in lavatory 45 cm 

Length of turning area in lavatory 85 cm 

Clear space on one side of lavatory bowl. 15 cm 

Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl
Distance from lavatory bowl to back wall 69 cm 

Lavatory bowl, height 43 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails No armrests 

Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. Yes
Height of wash basin89 cm
Clear space under wash basinYes
Height of soap dispenser118 cm
Distance to soap20 cm
Easy-to-operate inside lock Difficult to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 108 cm
Height of paper towel holder 137 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Guidedogs![]()
Access for guide dogsYes
Access for service dogs Yes
Indoor climate![]()
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedNo
Communication![]()
Orientation signage for essential facilities
Other information
Last update: 01-04-2026 (Version 2)
Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96
