Godadgang Logo

Ny Carlsberg Glyptotek - Niveau 3 øverst - Særudstilling

Ny Carlsberg Glyptotek - Niveau 3 øverst - Særudstilling

All information about Ny Carlsberg Glyptotek - Niveau 3 øverst - Særudstilling

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces  

Total number of parking spaces 

disabled parking signedYes

Surface marking of disabled parking spaces  Yes

Clear graphics  Yes

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt or tile

Disabled parking space, width  2.1 m Yellow

Way to the entrance

Distance from disabled parking space to main entrance  100 m

Distance from stopping zone to main entrance  20 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt or tile

Clear width in outdoor areas leading to main entrance  200 cm

Clear area, width 200 cm

Free area, height 300 cm

Levelfree access up to entrance  Yes

Curbs leveled outYes

slope on curb compensation15 %

Separation of forms of traffic up to main entrance  Yes

Height of separation 8 cm

Entrance to the building

Clear width at main entrance150 cm

Levelfree access through entranceYes

Entrance landings Yes

Size of the landing infront of the entrance150 cm

Clear width through entrance doors  90 cm

Height of door bell 136 cm Red

Entry phones with visual indication of active status  Yes

Entry phones with visual indication of connection  Yes

Entrance door, attractive and compressive force  2.5 kg

Door knobs and handles Relatively easy to operate

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign

Reception

Debit card machine, height  110 cm

Clear width in area leading to counter, etc 150 cm

Height of counter 110 cm

Shortest length of clear area in front of counter 200 cm

Counter illumination No

Induction loop at counter No

FM link at counter Yes

Interior design of the building

Level access to lifts Yes

Indicate depth of clear manoeuvring area measured at right angles to the door 180 cm

Lift door must be automatic No Red

Clear opening width of lift door  90 cm

Width of lift car  126 cm

Depth of lift car  105 cm Red

Floor buttons, lowest  130 cm

Floor buttons, highest 145 cm

Buttons with tactile-sense orientation  Yes

Are easy-touch buttons used? No

Number of support handles in lift  

Orientation signals (sound and light) in lift  Sound signal

Are floor levels announced by synthetic speech in lift?  No

Does a lamp indicate that the alarm has been activated?  No

Stair lift and lifting platform, capacity  250 kg

Lifting platform - platform length  140 cm

Lifting platform - platform width  90 cm

Width of doors in building  85 cm

Clear width, corridors  120 cm

Corridors free of furniture Yes

Gradients exceeding 1:20  (5%)No

Level-free circulation in building and level-free access to communal facilities  Yes

Attention fields in building  No

Distance between resting places in building  35 m

Back rests on resting places Yes

Arm rests on resting places Yes

Seating height of resting places 45 cm

Marking on steps  No marking

Handrails, position Both sides

Alternative to stairs (eg ramp, lift, stair lift)Yes

Distance between sources of lighting 3 m

Toilet facilities

accessible toilets at every levelYes

Entrance landings in front of the toiletYes

Guidedogs and indoor climate

Access for guide dogsYes

Access for service dogs Yes

Communal areas are non-smoking areas  Yes

Communal areas are pet-free areas  Yes

Signage in smoking and non-smoking areas  Yes

Signage indicates that pets are not allowedYes

Personal service  Yes

Distance to public transport 150 m

Free access for accompanying persons  Yes

Orientation signage for essential facilitiesGood signage in many places

Clear signage Very good sinage

Clear text on signs 

Sign contrasts 

Height of signs 160 cm

Simple and logically structured signs  Simple and logic

Alternative to guided tours, e.g. audioguides  

Tours with sign language interpretation  No

Accessibility-tested website 

Website may be read out loud No

 

Other information

Last update: 22-01-2014 (Version 1)

Ulla Kramer

Call us or write to us if you need more information about our services.

info@godadgang.dk - phone +45 51 34 35 96