Godadgang Logo

Nørrebrohallen - 1. Hal 1 (A og B)

Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)
Nørrebrohallen - 1. Hal 1 (A og B)

All information about Nørrebrohallen - 1. Hal 1 (A og B)

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces  

Total number of parking spaces 30 

disabled parking signedNo

Surface marking of disabled parking spaces  Yes

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt

Disabled parking space, width  3.5 m

Number of parking spaces for vans  

Distance from disabled parking space to main entrance  30 m

Distance from stopping zone to main entrance  30 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  tiles

Clear width in outdoor areas leading to main entrance  150 cm

Clear area, width 150 cm

Free area, height 250 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Levelled out on ground

Gradient of levelling  2 %

Curbs leveled outYes

Entrance to the building

Clear width at main entrance250 cm

Levelfree access through entranceYes

Height of threshold1 cm

Marking of doorstepsYes

Entrance landings Yes

Size of levelfree landings in front of entrance(s)250 cm

Clear width through entrance doors  180 cm

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign and changed surfacing

Glass panel with horizontal marking  Poor marking in several places

Reception

Clear width in area leading to counter, etc 250 cm

Height of counter 103 cm

Shortest length of clear area in front of counter 250 cm

Counter illumination No

Induction loop at counter No

Debit card machine, height  133 cm

Handicaptoilet i foyeren

Entrance landings in front of the toiletYes

Lavatory door, width  86 cm

Lavatory doors can be opened/closed using a tractive or compressive force of  2.5 kg

Clear manoeuvring area in lavatories  Yes

Width of turning area in lavatory  150 cm

Length of turning area in lavatory  160 cm

Clear space on one side of lavatory bowl.  160 cm

Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl

Distance from lavatory bowl to back wall  74 cm

Lavatory bowl, height  48 cm

Operation of toilet flushing handleFlushing is elevated

Lavatory, position of support rails  Right and left side

Easy-to-operate taps Easy to operate

Possible to use washbasin when sitting on lavatory bowl.  Yes

Height of wash basin78 cm

Clear space under wash basinYes

Height of soap dispenser98 cm

Distance to soap60 cm

Easy-to-operate inside lock Difficult to operate

Locked doors can be opened from the outside in case of emergency  Yes

Height of hand drier button120 cm

Ventilation system in lavatories  Yes

Wipeable surfaces  Yes

Non-glare illuminated mirror within easy reach   Yes

Interior pull handleNo

Indretning af Hal 1 (A og B)

Width of doors in building  160 cm

Clear width, corridors  150 cm

Gradients exceeding 1:20  (5%)Yes Red

Ramp with gradient of  24 % Red

Attention fields in building  No

Marking on steps  First and last steps and others

Permanent railing at free-standing stairs  No protection Red

Handrails, position Both sides

Alternative to stairs (eg ramp, lift, stair lift)Yes

Distance between sources of lighting 3 m

omklædnings- og bruserum i Hal 1 (A og B)

Changing room benches, width  43 cm

Changing room benches, length  250 cm

Changing room benches, seating height  45 cm

Lower clothing hooks, height  152 cm

Anti-glare mirror Yes

Closed changing cubicleNo

Clear area in changing cubicle with room for an assistant 210 cm

Separate changing rooms No

Clear manoeuvring area in bathrooms  Yes

Vendeareal ved bruseplads (bredde)235 cm

Vendeareal ved bruseplads (længde)270 cm

Bathroom mirror, height of lower edge  129 cm

Ventilation system in bathrooms and swimming pool area.  Yes

Possibility of wiping all surfaces with damp cloth?  Yes

Non-glare illuminated mirror in bathrooms? Yes

Access to shower  from all sides

Operation of shower Standing and sitting

Type of showerShower not adjustable

Minimum height for wall position of shower217 cm Red

Shower seat/stool  Neither shower seat nor shower stool Red

Walls with horizontal handrails in shower  

Walls with vertical handrails in shower 

Shower temperature and water controls easy to operateNo Red

Height of water and temperature control devices108 cm

Indretning sports- og træningsfaciliteter

Clear width of footway around pitch 150 cm

Generelle forhold

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedYes

Orientation signage for essential facilitiesGood signage in many places

 

Other information

Last update: 12-07-2023 (Version 1)