Nationalmuseet - 1.sal
All information about Nationalmuseet - 1.sal
Information for

Accessibility information
Way to the entrance![]()
Number of disabled parking spaces 4
disabled parking signedYes
Surface marking of disabled parking spaces Yes
Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementasphalt
Disabled parking space, width 2 m 

Entrance to the building![]()
Distance from disabled parking space to main entrance 25 m
Distance from stopping zone to main entrance 20 m
Back rests Yes
Suitable back rests Yes
Seating height/sitting height of resting places 48 cm
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance setts
Clear width in outdoor areas leading to main entrance 140 cm
Clear area, width 200 cm
Free area, height 500 cm
Levelfree access up to entrance No
Type of levelling up to entrance Levelled out on ground
Gradient of levelling 5 %
Hight of steps5 cm
Handrail position next to steps No handrail 

Separation of forms of traffic up to main entrance Yes
Height of separation 5 cm
Outdoor areas![]()
Clear width at main entrance200 cm
Levelfree access through entranceYes
Entrance landings Yes
Size of the landing infront of the entrance200 cm
Size of the landing infront of the entrance200 cm
Clear width through entrance doors 105 cm
Entrance door, attractive and compressive force 3.5 kg
Door knobs and handles Very easy to operate
Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas With sign and changed surfacing
Glass panel with horizontal marking Reasonable marking in several places
Access for guide dogsYes
Access for service dogs Yes
Guidedogs and indoor climate![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 300 cm
Lift door must be automatic Yes
Clear opening width of lift door 90 cm
Width of lift car 180 cm
Depth of lift car 130 cm 

Floor buttons, lowest 110 cm
Floor buttons, highest 130 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 3
Orientation signals (sound and light) in lift Sound/light signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? No
Døre bortset fra indgangsdøre![]()
Width of doors in building 80 cm
Height of thresholds in building 3.5 cm
Are there wedges at thresholds in excess of 2.5 cm? Yes
Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg
Indvendige gange og ramper![]()
Clear width, corridors 130 cm
Corridors free of furniture Yes
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Distance between resting places in building 60 m
Back rests on resting places Yes
Arm rests on resting places Yes
Seating height of resting places 46 cm
Distance between sources of lighting 6 m
Indretning af toilet- og baderum![]()
Entrance landings in front of the toiletYes
Lavatory door, width 77 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Clear manoeuvring area in lavatories Yes
Width of turning area in lavatory 180 cm
Length of turning area in lavatory 210 cm
Clear space on one side of lavatory bowl. 160 cm
Position of clear space next to the lavatory bowlOn one side of lavatory bowl
Distance from lavatory bowl to back wall 70 cm
Lavatory bowl, height 46 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails Right and left side
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. Yes
Height of wash basin83 cm
Clear space under wash basinYes
Easy-to-operate inside lock Easy to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 85 cm
Height of paper towel holder 125 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Information, formidling og service![]()
Mechanical ventilation Yes
Communal areas are pet-free areas Yes
Orientation signage for essential facilitiesRelatively good signage
Simple and logically structured signs Very simple and logic
Alternative to guided tours, e.g. audioguides
Tours with sign language interpretation No
Subtitled information films Yes
Personal service Yes
Distance to public transport 50 m
Free access for accompanying persons Yes
Other information
Last update: 18-01-2023 (Version 1)

Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96