All information about Løvel Hallen

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces   Red

Total number of parking spaces 30 

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt or tile

Distance from disabled parking space to main entrance  15 m

Distance from stopping zone to main entrance  15 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt or tile

Clear width in outdoor areas leading to main entrance  100 cm

Clear area, width 250 cm

Free area, height 250 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Levelled out on ground

Gradient of levelling  2 %

Entrance to the building

Clear width at main entrance250 cm

Levelfree access through entranceYes

Height of threshold8 cm

Tresholds levelled out by sloping wedge No Red

Marking of doorstepsYes

Entrance landings Yes

Size of the landing infront of the entrance250 cm

Clear width through entrance doors  77 cm

Entrance door, attractive and compressive force  7 kg Red

Door knobs and handles Easy to operate

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign and changed surfacing

Glass panel with horizontal marking  Good marking in several places

Reception

Entrance landings in front of the toiletYes

Lavatory door, width  77 cm

Lavatory doors can be opened/closed using a tractive or compressive force of  2.5 kg

Clear manoeuvring area in lavatories  Yes

Width of turning area in lavatory  150 cm

Length of turning area in lavatory  150 cm

Clear space on one side of lavatory bowl.  90 cm

Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl

Distance from lavatory bowl to back wall  70 cm

Lavatory bowl, height  41 cm Red

Operation of toilet flushing handleFlushing is elevated

Lavatory, position of support rails  Right and left side

Easy-to-operate taps Difficult to operate Red

Possible to use washbasin when sitting on lavatory bowl.  Yes

Height of wash basin80 cm

Clear space under wash basinYes

Height of soap dispenser100 cm

Distance to soap40 cm

Easy-to-operate inside lock Difficult to operate

Locked doors can be opened from the outside in case of emergency  Yes

Mirror, lower edge  90 cm

Height of paper towel holder 118 cm

Ventilation system in lavatories  Yes

Wipeable surfaces  Yes

Non-glare illuminated mirror within easy reach   Yes

Interior pull handleYes

Bygningsindretning generelt

Width of doors in building  77 cm

Doors, attractive/compressive force (heaviest non-entrance door) 7 kg Red

Clear width, corridors  150 cm

Corridors free of furniture Yes

Gradients exceeding 1:20  (5%)No

Level-free circulation in building and level-free access to communal facilities  Yes

Distance between sources of lighting 3 m

Omklædningsfaciliteter

Changing room benches, width  35 cm

Changing room benches, length  200 cm

Changing room benches, seating height  45 cm

Lower clothing hooks, height  145 cm

Anti-glare mirror Yes

Closed changing cubicleNo

Separate changing rooms No

Toiletter og badefaciliteter

Clear manoeuvring area in lavatories  No Red

Clear manoeuvring area in bathrooms  Yes

Vendeareal ved bruseplads (bredde)350 cm

Vendeareal ved bruseplads (længde)250 cm

Bathroom mirror, height of lower edge  90 cm

Ventilation system in bathrooms and swimming pool area.  Yes

Possibility of wiping all surfaces with damp cloth?  Yes

Access to shower  from all sides

Operation of shower Standing and sitting

Type of showerShower not adjustable

Minimum height for wall position of shower205 cm

Maximum height of shower on wall205 cm

Shower seat/stool  Neither shower seat nor shower stool Red

Walls with horizontal handrails in shower  

Walls with vertical handrails in shower 

Shower temperature and water controls easy to operateYes

Height of water and temperature control devices110 cm

Indretning sports- og træningsfaciliteter

Paving on path around pitch 

Level access to lifts Yes

Indicate depth of clear manoeuvring area measured at right angles to the door 150 cm

Lift door must be automatic No

Clear opening width of lift door  90 cm

Width of lift car  100 cm

Depth of lift car  140 cm

Floor buttons, lowest  85 cm

Floor buttons, highest 85 cm

Buttons with tactile-sense orientation  Yes

Are easy-touch buttons used? No

Number of support handles in lift  

Orientation signals (sound and light) in lift  Sound signal

Are floor levels announced by synthetic speech in lift?  No

Attention fields in building  No

Marking on steps  All steps

Marked surfaces Tread

Handrails, position One side Red

Alternative to stairs (eg ramp, lift, stair lift)Yes

Generelle forhold

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedNo

Orientation signage for essential facilitiesGood signage in many places

Distance to public transport 300 m

Accessibility-tested website 

Website may be read out loud Yes

 

Other information

Last update: 18-10-2017 (Version 1)

Ulla Kramer

Call us or write to us if you need more information about our services.

info@godadgang.dk - phone +45 51 34 35 96