Parking facilities![]()
Number of disabled parking spaces 1
Total number of parking spaces 65
disabled parking signedYes
Surface marking of disabled parking spaces No 

Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementtiles
Distance from disabled parking space to main entrance 45 m
Distance from stopping zone to main entrance 30 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance tiles
Clear width in outdoor areas leading to main entrance 300 cm
Clear area, width 300 cm
Free area, height 300 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Levelled out on ground
Gradient of levelling 4 %
Entrance to the building![]()
Clear width at main entrance300 cm
Levelfree access through entranceYes
Height of threshold2.5 cm
Gradient of wedge at thresholds 30 %
Entrance landings No 

Size of the landing infront of the entrance100 cm 

Openings in grating (to protect guide dogs), length at main entrance 3.5 cm 

Openings in grating (to protect guide dogs), width at main entrance 3.5 cm
Clear width through entrance doors 81 cm
Door knobs and handles Easy to operate
Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas With sign and changed surfacing
Interior design of the school![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 300 cm
Lift door must be automatic Yes
Clear opening width of lift door 90 cm
Width of lift car 130 cm
Depth of lift car 130 cm 

Floor buttons, lowest 90 cm
Floor buttons, highest 110 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 1
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? No
Attention fields in building No
Marking on steps All steps
Handrails, position Both sides
Alternative to stairs (eg ramp, lift, stair lift)Yes
Width of doors in building 76 cm 

Clear width, corridors 130 cm
Corridors free of furniture Yes
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Distance between sources of lighting 3 m
Indretning af undervisningslokaler og fælleslokaler![]()
Clear height under work table 70 cm
Shortest length of clear manoeuvring area in front of table 130 cm
Chair with backrest at work table Yes
Seat height of chair at work table 45 cm
Induction loop systems can be booked No 

Sockets for notetaker's equipment Yes
Powerbeam screen Yes
Interior design of the classrooms![]()
Entrance landings in front of the toiletYes
Lavatory door, width 87 cm
Lavatory threshold, height 0 cm
Width of turning area in lavatory 150 cm
Length of turning area in lavatory 150 cm
Clear space on one side of lavatory bowl. 79 cm 

Position of clear space next to the lavatory bowlOn the left-hand side of the lavatory bowl
Distance from lavatory bowl to back wall 73 cm
Lavatory bowl, height 44.5 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails No armrests 

Easy-to-operate taps Very easy to operate
Possible to use washbasin when sitting on lavatory bowl. Yes
Height of wash basin80 cm
Clear space under wash basinYes
Height of soap dispenser95 cm
Distance to soap40 cm
Easy-to-operate inside lock Difficult to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 120 cm
Height of hand drier button80 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Outdoor areas![]()
Entrance landings No 

Surfacing of outdoor areas is firm and evenYes
Surfacing of outdoor areas, general Asphalt
Levelfree trails or pathsYes
Type of levelling in outdoor areas, general Ramp
Gradient of levelling 17 % 

Guidedogs and indoor climate![]()
Access for guide dogsYes
Access for service dogs Yes
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedNo
Allergy-friendly cleaning mainly allergiapproved detergents
Thorough cleaning, other rooms quaterly
Wall-to-wall carpeting used No
Wipeable surfaces Yes
Wipeable lamps and furniture Yes
Orientation signage for essential facilitiesRelatively good signage
Distance to public transport 45 m
Other information