Godadgang Logo

Kirke Hyllinge Skole - 2. Sidebygning

Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning
Kirke Hyllinge Skole - 2. Sidebygning

All information about Kirke Hyllinge Skole - 2. Sidebygning

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces   Red

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt or tile

Clear width in outdoor areas leading to main entrance  130 cm

Clear area, width 130 cm

Free area, height 250 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Levelled out on ground

Gradient of levelling  5 %

Hight of steps15 cm

Handrail position next to steps  Red

Entrance to the building

Clear width at main entrance250 cm

Levelfree access through entranceYes

Height of threshold4.5 cm

Tresholds levelled out by sloping wedge No Red

Marking of doorstepsYes

Entrance landings Yes

Size of the landing infront of the entrance250 cm

Openings in grating (to protect guide dogs), length at main entrance  3 cm Red

Openings in grating (to protect guide dogs), width at main entrance  3 cm Red

Clear width through entrance doors  81 cm

Entrance door, attractive and compressive force  5 kg Red

Door knobs and handles Easy to operate

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  Not marked

Glass panel with horizontal marking  Poor marking in several places

Interior design of the school

Width of doors in building  84 cm

Doors, attractive/compressive force (heaviest non-entrance door) 5 kg Red

Clear width, corridors  130 cm

Corridors free of furniture Yes

Gradients exceeding 1:20  (5%)No

Level-free circulation in building and level-free access to communal facilities  No Red

Attention fields in building  No

Marking on steps  No marking

Handrails, position One side Red

Alternative to stairs (eg ramp, lift, stair lift)No Red

Distance between sources of lighting 3 m

Indretning af undervisningslokaler i sidebygningen

Levelfree access to the room and the boardYes

Sockets for notetaker's equipment  Yes

Powerbeam screen  Yes

Interior design of the classrooms

Entrance landings in front of the toiletNo Red

Lavatory door, width  86 cm

Lavatory doors can be opened/closed using a tractive or compressive force of  2.5 kg

Width of turning area in lavatory  165 cm

Length of turning area in lavatory  130 cm Red

Clear space on one side of lavatory bowl.  90 cm

Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl

Distance from lavatory bowl to back wall  72 cm

Lavatory bowl, height  44 cm Red

Operation of toilet flushing handleFlushing can be operated with more than 1 finger

Lavatory, position of support rails  No armrests Red

Easy-to-operate taps Easy to operate

Possible to use washbasin when sitting on lavatory bowl.  No

Height of wash basin89 cm

Clear space under wash basinYes

Height of soap dispenser106 cm

Distance to soap40 cm

Easy-to-operate inside lock Difficult to operate

Locked doors can be opened from the outside in case of emergency  Yes

Mirror, lower edge  131 cm

Height of paper towel holder 115 cm

Ventilation system in lavatories  Yes

Wipeable surfaces  Yes

Non-glare illuminated mirror within easy reach   Yes

Interior pull handleNo

Guidedogs and indoor climate

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedNo

Allergy-friendly cleaning  mainly allergiapproved detergents

Thorough cleaning, other rooms  yearly

Wall-to-wall carpeting used  No

Wipeable surfaces Yes

Wipeable lamps and furniture  Yes

Orientation signage for essential facilitiesRelatively good signage

Accessibility-tested website 

Website may be read out loud No

 

Other information

Last update: 14-12-2021 (Version 1)

Ulla Kramer

Call us or write to us if you need more information about our services.

info@godadgang.dk - phone +45 51 34 35 96