Jobcenter København - Lærkevej - 1. sal
All information about Jobcenter København - Lærkevej - 1. sal
Information for

Accessibility information
Parking facilities![]()
Number of disabled parking spaces 2
disabled parking signedYes
Surface marking of disabled parking spaces Yes
Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementasphalt
Disabled parking space, width 2.1 m 

Number of parking spaces for vans 0
Way to the entrance![]()
Distance from disabled parking space to main entrance 85 m
Distance from stopping zone to main entrance 20 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance asphalt or tile
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 150 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Curbs leveled outYes
slope on curb compensation30 % 

Entrance to the building![]()
Clear width at main entrance150 cm
Position of handrails Both sides
Rise of steps 15 cm
Entrance landings Yes
Size of levelfree landings in front of entrance(s)150 cm
Clear width through entrance doors 114 cm
Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas With sign and changed surfacing
Glass panel with horizontal marking Poor marking in several places
Reception and waiting area![]()
Names called out Yes
Getting around in the building![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 150 cm
Lift door must be automatic No 

Clear opening width of lift door 82 cm
Width of lift car 135 cm
Depth of lift car 110 cm 

Floor buttons, lowest 107 cm
Floor buttons, highest 134 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 0
Orientation signals (sound and light) in lift Sound/light signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? Yes
Marking on steps First and last steps and others
Handrails, position One side 

Alternative to stairs (eg ramp, lift, stair lift)Yes
Attention fields in building No
Clear width, corridors 160 cm
Corridors free of furniture Yes
Gradients exceeding 1:20 (5%)No
Shortest length of clear manoeuvring area 150 cm
Clear manoeuvring area of 150 x 150 cm Yes
Distance between resting places in building 20 m
Back rests on resting places Yes
Arm rests on resting places Yes
Distance between sources of lighting 3 m
Personal escort Yes
Interior design of the building![]()
Width of doors in building 77 cm
Doors, attractive/compressive force (heaviest non-entrance door) 1 kg
Chairs with armrests available. Yes
Chairs with backrests available Yes
Seating height of chairs 45 cm
Clearance under tables 70 cm
Clear depth under table50 cm
Sockets for notetaker's equipment Yes
Meeting facilities![]()
accessible toilets at every levelYes
Entrance landings in front of the toiletYes
Lavatory door, width 86 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 1 kg
Clear manoeuvring area in lavatories No 

Width of turning area in lavatory 140 cm 

Length of turning area in lavatory 110 cm 

Clear space on one side of lavatory bowl. 104 cm
Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl
Distance from lavatory bowl to back wall 72 cm
Lavatory bowl, height 44 cm 

Operation of toilet flushing handleFlushing can only be operated with 1 finger
Lavatory, position of support rails Right side 

Easy-to-operate taps Difficult to operate 

Possible to use washbasin when sitting on lavatory bowl. No
Height of wash basin85 cm
Clear space under wash basinYes
Height of soap dispenser110 cm
Distance to soap40 cm
Easy-to-operate inside lock Difficult to operate
Locked doors can be opened from the outside in case of emergency Yes
Height of paper towel holder 120 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleNo
Guidedogs and indoor climate![]()
Access for guide dogsYes
Access for service dogs Yes
Mechanical ventilation Yes
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedYes
Information![]()
Orientation signage for essential facilitiesGood signage everywhere
Personal service Yes
Distance to public transport 400 m
Website may be read out loud Yes
Other information
Last update: 09-08-2019 (Version 1)

Call us or write to us if you need more information about our services.
info@godadgang.dk - phone +45 51 34 35 96