Godadgang Logo

Hørsholm Skole - 3. Bygning B - Kontor / administration

Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration
Hørsholm Skole -  3. Bygning B - Kontor / administration

All information about Hørsholm Skole - 3. Bygning B - Kontor / administration

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces  

Total number of parking spaces 45 

disabled parking signedYes

Surface marking of disabled parking spaces  Yes

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt or tile

Disabled parking space, width  3.5 m

Number of parking spaces for vans  

Distance from disabled parking space to main entrance  150 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt or tile

Clear width in outdoor areas leading to main entrance  150 cm

Clear area, width 250 cm

Free area, height 250 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Ramp

Gradient of levelling  9 % Yellow

Stair lift and lifting platform, capacity  300 kg

Lifting platform - platform length  140 cm

Lifting platform - platform width  110 cm

Entrance to the building

Clear width at main entrance200 cm

Levelfree access through entranceYes

Position of handrails Both sides

Rise of steps 15 cm

Height of threshold2.5 cm

Marking of doorstepsYes

Stair lift and lifting platform, capacity  225 kg

Lifting platform - platform length  100 cm

Lifting platform - platform width  80 cm

Entrance landings Yes

Size of the landing infront of the entrance200 cm

Clear width through entrance doors  93 cm

Entrance door, attractive and compressive force  4 kg

Door knobs and handles Easy to operate

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign

Interior design of the school

Width of doors in building  74 cm Red

Doors, attractive/compressive force (heaviest non-entrance door) 4 kg

Gradients exceeding 1:20  (5%)No

Level-free circulation in building and level-free access to communal facilities  Yes

Distance between sources of lighting 3 m

Toiletter

Entrance landings in front of the toiletYes

Lavatory door, width  85 cm

Lavatory doors can be opened/closed using a tractive or compressive force of  2.5 kg

Width of turning area in lavatory  160 cm

Length of turning area in lavatory  210 cm

Clear space on one side of lavatory bowl.  108 cm

Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl

Distance from lavatory bowl to back wall  70 cm

Lavatory bowl, height  40 cm Red

Operation of toilet flushing handleFlushing is elevated

Lavatory, position of support rails  No armrests Red

Easy-to-operate taps Relatively easy to operate

Possible to use washbasin when sitting on lavatory bowl.  No Red

Height of wash basin86 cm

Clear space under wash basinYes

Height of soap dispenser105 cm

Distance to soap20 cm

Easy-to-operate inside lock Difficult to operate

Locked doors can be opened from the outside in case of emergency  Yes

Mirror, lower edge  126 cm

Height of towel roll115 cm

Ventilation system in lavatories  Yes

Wipeable surfaces  Yes

Non-glare illuminated mirror within easy reach   Yes

Interior pull handleNo

Guidedogs and indoor climate

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedNo Red

Allergy-friendly cleaning  mainly allergiapproved detergents

Thorough cleaning, other rooms  yearly

Wall-to-wall carpeting used  No

Wipeable surfaces Yes

Wipeable lamps and furniture  Yes

Orientation signage for essential facilitiesGood signage in many places

Distance to public transport 250 m

Accessibility-tested website 

Website may be read out loud No

 

Other information

Last update: 13-10-2015 (Version 1)

Ulla Kramer

Call us or write to us if you need more information about our services.

info@godadgang.dk - phone +45 51 34 35 96