Godadgang Logo

Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO

Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO
Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO

All information about Gyvelhøjskolen - 1. Bygning A - Indskoling / SFO

Information for
Info ALL
Accessibility information

Parking facilities

Number of disabled parking spaces   Red

Total number of parking spaces 50 

Surfacing on disabled parking spaces The surfacing is even, firm and intact

Type of pavementasphalt or tile

Distance from disabled parking space to main entrance  130 m

Distance from stopping zone to main entrance  20 m

Surfacing on outdoor walkways to the entrance is firm and intactYes

Type of surfacing in outdoor areas leading to main entrance  asphalt or tile

Clear width in outdoor areas leading to main entrance  150 cm

Clear area, width 150 cm

Free area, height 250 cm

Levelfree access up to entrance  Yes

Type of levelling up to entrance  Ramp

Gradient of levelling  10 % Red

Curbs leveled outNo Red

Hight of steps15 cm

Handrail position next to steps No handrail Red

Entrance to the building

Clear width at main entrance250 cm

Levelfree access through entranceYes

Height of threshold3.5 cm

Tresholds levelled out by sloping wedge No Red

Marking of doorstepsYes

Entrance landings Yes

Size of the landing infront of the entrance250 cm

Clear width through entrance doors  73 cm Red

Entrance door, attractive and compressive force  5 kg Red

Door knobs and handles Easy to operate

Design of locking devices Difficult to operate Red

Lighting at entrance doors, reception, lobby, etc  Yes

Marking of entrances by signs or changed surfacing in circulation areas  With sign and changed surfacing

Interior design of the school

Level access to lifts Yes

Indicate depth of clear manoeuvring area measured at right angles to the door 170 cm

Lift door must be automatic Yes

Clear opening width of lift door  85 cm

Width of lift car  110 cm

Depth of lift car  170 cm

Floor buttons, lowest  99 cm

Floor buttons, highest 108 cm

Buttons with tactile-sense orientation  Yes

Are easy-touch buttons used? No

Number of support handles in lift  

Orientation signals (sound and light) in lift  Sound signal

Are floor levels announced by synthetic speech in lift?  No

Does a lamp indicate that the alarm has been activated?  Yes

Width of doors in building  77 cm

Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg

Clear width, corridors  150 cm

Corridors free of furniture Yes

Gradients exceeding 1:20  (5%)No

Level-free circulation in building and level-free access to communal facilities  Yes

Attention fields in building  No

Marking on steps  All steps

Handrails, position One side Red

Alternative to stairs (eg ramp, lift, stair lift)Yes

Distance between sources of lighting 3 m

Toiletter

Lavatory door, width  65 cm Red

Interior design of the classrooms

Induction loop in communal room with microphone No

Sockets for notetaker's equipment  Yes

Powerbeam screen  Yes

Outdoor areas

Levelfree trails or pathsNo Red

Guidedogs and indoor climate

Access for guide dogsYes

Access for service dogs Yes

Communal areas are pet-free areas  Yes

Signage indicates that pets are not allowedNo

Allergy-friendly cleaning  mainly allergiapproved detergents

Thorough cleaning, other rooms  yearly

Wall-to-wall carpeting used  No

Wipeable surfaces Yes

Wipeable lamps and furniture  Yes

Orientation signage for essential facilitiesRelatively good signage

Website may be read out loud Yes

 

Other information

Last update: 06-10-2020 (Version 1)

Ulla Kramer