Sundbyøsterhallerne - Hal 2 og Bevægelsessalen
All information about Sundbyøsterhallerne - Hal 2 og Bevægelsessalen
Information for

Accessibility information
Parking facilities![]()
Number of disabled parking spaces 3
disabled parking signedNo
Surface marking of disabled parking spaces Yes
Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementasphalt
Disabled parking space, width 3.5 m
Distance from disabled parking space to main entrance 20 m
Distance from stopping zone to main entrance 5 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance tiles
Clear width in outdoor areas leading to main entrance 200 cm
Clear area, width 200 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Levelled out on ground
Gradient of levelling 4 %
Curbs leveled outYes
slope on curb compensation10 %
Entrance to the building![]()
Clear width at main entrance250 cm
Levelfree access through entranceYes
Height of threshold0 cm
Marking of doorstepsYes
Entrance landings No 

Openings in grating (to protect guide dogs), length at main entrance 0.9 cm
Openings in grating (to protect guide dogs), width at main entrance 3 cm
Clear width through entrance doors 170 cm
Design of locking devices Difficult to operate 

Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas With sign 

Glass panel with horizontal marking Poor marking in several places
Bygningsindretning generelt![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 250 cm
Lift door must be automatic Yes
Clear opening width of lift door 90 cm
Width of lift car 110 cm
Depth of lift car 210 cm
Floor buttons, lowest 90 cm
Floor buttons, highest 120 cm
Buttons with tactile-sense orientation Yes
Are easy-touch buttons used? No
Number of support handles in lift 1
Orientation signals (sound and light) in lift Sound signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? Yes
Width of doors in building 90 cm
Doors, attractive/compressive force (heaviest non-entrance door) 6 kg 

Clear width, corridors 150 cm
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Attention fields in building No
Marking on steps No marking
Handrails, position One side 

Alternative to stairs (eg ramp, lift, stair lift)Yes
Distance between sources of lighting 3 m
Handicaptoilet på 1. sal og 2. sal![]()
Entrance landings in front of the toiletYes
Lavatory door, width 87 cm
Lavatory threshold, height 1 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Clear manoeuvring area in lavatories Yes
Width of turning area in lavatory 190 cm
Length of turning area in lavatory 250 cm
Clear space on one side of lavatory bowl. 130 cm
Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl
Distance from lavatory bowl to back wall 70 cm
Lavatory bowl, height 52 cm 

Operation of toilet flushing handleFlushing is elevated
Lavatory, position of support rails Right and left side
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. Yes
Height of wash basin78 cm
Clear space under wash basinYes
Height of soap dispenser103 cm
Easy-to-operate inside lock Difficult to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 80 cm
Height of hand drier button80 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Omklædningsfaciliteter![]()
Width of doors in building 87 cm
Doors, attractive/compressive force (heaviest non-entrance door) 2.5 kg
Changing room benches, width 35 cm
Changing room benches, length 300 cm
Changing room benches, seating height 45 cm
Lower clothing hooks, height 145 cm
Anti-glare mirror Yes
Closed changing cubicleNo
Minimum dimensions of clear area in changing cubicles 150 cm
Separate changing rooms No
accessible toilets at every levelYes
Clear manoeuvring area in bathrooms Yes
Vendeareal ved bruseplads (bredde)280 cm
Vendeareal ved bruseplads (længde)270 cm
Bathroom mirror, height of lower edge 90 cm
Ventilation system in bathrooms and swimming pool area. Yes
Possibility of wiping all surfaces with damp cloth? Yes
Non-glare illuminated mirror in bathrooms? Yes
Access to shower from all sides
Change in level at shower 0 cm
Operation of shower Standing and sitting
Type of showerShower not adjustable
Minimum height for wall position of shower203 cm 

Shower seat/stool Neither shower seat nor shower stool 

Walls with horizontal handrails in shower 0
Walls with vertical handrails in shower 0
Shower temperature and water controls easy to operateYes
Height of water and temperature control devices112 cm
Indretning sports- og træningsfaciliteter![]()
Clear width of footway around pitch 150 cm
Generelle forhold![]()
Access for guide dogsYes
Access for service dogs Yes
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedNo
Orientation signage for essential facilitiesGood signage in many places
Accessibility-tested website
Website may be read out loud Yes
Other information
Last update: 11-11-2023 (Version 1)

Call us or write to us if you need more information about our services.