Parking facilities![]()
Number of disabled parking spaces 0 

Total number of parking spaces 4
Surfacing on disabled parking spaces The surfacing is even, firm and intact
Type of pavementasphalt or tile
Disabled parking space, width 2.3 m 

Number of parking spaces for vans 0
Way to the entrance![]()
Distance from disabled parking space to main entrance 45 m
Distance from stopping zone to main entrance 45 m
Surfacing on outdoor walkways to the entrance is firm and intactYes
Type of surfacing in outdoor areas leading to main entrance asphalt or tile
Clear width in outdoor areas leading to main entrance 150 cm
Clear area, width 150 cm
Free area, height 250 cm
Levelfree access up to entrance Yes
Type of levelling up to entrance Ramp
Gradient of levelling 8 % 

Handrail position next to steps No handrail 

Entrance to the building![]()
Clear width at main entrance250 cm
Levelfree access through entranceYes
Rise of steps 18 cm
Height of threshold4 cm
Tresholds levelled out by sloping wedge No 

Marking of doorstepsYes
Entrance landings Yes
Size of the landing infront of the entrance250 cm
Clear width through entrance doors 80 cm
Entrance door, attractive and compressive force 5 kg 

Door knobs and handles Difficult to operate 

Design of locking devices Difficult to operate 

Lighting at entrance doors, reception, lobby, etc Yes
Marking of entrances by signs or changed surfacing in circulation areas Not marked
Glass panel with horizontal marking Reasonable marking in several places
Reception![]()
FM link at counter Yes
Interior design of the building![]()
Level access to lifts Yes
Indicate depth of clear manoeuvring area measured at right angles to the door 150 cm
Lift door must be automatic Yes
Clear opening width of lift door 89 cm
Width of lift car 130 cm
Depth of lift car 135 cm 

Floor buttons, lowest 119 cm
Floor buttons, highest 106 cm
Buttons with tactile-sense orientation Partly
Are easy-touch buttons used? No
Number of support handles in lift 0
Orientation signals (sound and light) in lift Sound signal
Are floor levels announced by synthetic speech in lift? No
Does a lamp indicate that the alarm has been activated? No
Width of doors in building 76 cm 

Height of thresholds in building 4 cm
Are there wedges at thresholds in excess of 2.5 cm? No 

Doors, attractive/compressive force (heaviest non-entrance door) 5 kg 

Clear width, corridors 150 cm
Corridors free of furniture Yes
Gradients exceeding 1:20 (5%)No
Level-free circulation in building and level-free access to communal facilities Yes
Meeting and conference facilities![]()
Entrance landings in front of the toiletYes
Lavatory door, width 86 cm
Lavatory doors can be opened/closed using a tractive or compressive force of 2.5 kg
Width of turning area in lavatory 50 cm 

Length of turning area in lavatory 50 cm 

Clear space on one side of lavatory bowl. 40 cm 

Position of clear space next to the lavatory bowlOn the right-hand side of the lavtory bowl
Distance from lavatory bowl to back wall 53 cm 

Lavatory bowl, height 46 cm 

Operation of toilet flushing handleFlushing can be operated with more than 1 finger
Lavatory, position of support rails Right and left side
Easy-to-operate taps Easy to operate
Possible to use washbasin when sitting on lavatory bowl. No 

Height of wash basin83 cm
Clear space under wash basinYes
Height of soap dispenser83 cm
Easy-to-operate inside lock Easy to operate
Locked doors can be opened from the outside in case of emergency Yes
Mirror, lower edge 100 cm
Ventilation system in lavatories Yes
Wipeable surfaces Yes
Non-glare illuminated mirror within easy reach Yes
Interior pull handleYes
Attention fields in building No
Marking on steps All steps
Marked surfaces Tread and riser
Handrails, position Both sides
Alternative to stairs (eg ramp, lift, stair lift)Yes
Distance between sources of lighting 3 m
Toilet facilities![]()
Chairs with armrests available. No 

Chairs with backrests available Yes
Seating height of chairs 45 cm
Clearance under tables 68 cm
Clear depth under table80 cm
Levelfree access to the room and the boardYes
Induction loop systems can be booked No 

Sockets for notetaker's equipment Yes
Powerbeam screen Yes
Guidedogs and indoor climate![]()
Access for guide dogsYes
Access for service dogs Yes
Communal areas are pet-free areas Yes
Signage indicates that pets are not allowedNo 

Wall-to-wall carpeting used No
Wipeable surfaces Yes
Wipeable lamps and furniture Yes
Orientation signage for essential facilitiesGood signage in many places
Distance to public transport 150 m
Distance to kiosk 0 km
Accessibility-tested website
Other information
Last update: 07-09-2016 (Version 1)